Non-Addressable Control Panel (4002-10)

SKU: 4002-10
Category: , ,
Original price was: ₱37,000.80.Current price is: ₱21,549.27.
  • 16 detection zone model
  • Clear alarm zone LED indicators, with a single indicator for indication of fault, disable and test condition
  • Configurable non-blocking alarm zones
  • Configurable alarm dependency (zone coincidence detection)
  • Configurable timer to delay output activation (up to 10 min)
  • End of line device with condenser
  • 3 access levels
  • Single test mode
  • Configurable day / night mode
  • Manual activation of alarm devices.
  • Supervised auxiliary output DC 24 V
  • 2 conventional programmable audio / visual alarm output circuits.
  • 2 unsupervised relay contacts for fire alarm condition outputs
  • 1 unsupervised relay contact for fault condition output.
  • 3 voltage free inputs for remote reset and evacuation start / stop and day / night mode.
  • Supports up to 7 repeater panels
  • Red surface mount metal enclosure.

6 in stock

General Overview

  • The 4002‑10 is a conventional (non‑addressable) fire alarm control panel.

  • It has a metal enclosure (red finish) for durability and visibility.

  • Designed to handle 16 detection zones.

  • Each zone can support up to 32 non-addressable devices (such as standard smoke or heat detectors) per alarm circuit.

  • The zones are configurable: you can set them to be non‑latching (i.e., they don’t stay latched after alarm) if needed.

  • There’s a feature for alarm dependency (coincidence detection): this means you can require more than one zone to go into alarm before triggering certain outputs, improving fault tolerance.

  • There is a configurable delay timer (up to 10 minutes) before outputs are activated — useful for staged alarms or to prevent false activation.

Supervision & End‑of‑Line

  • Uses a capacitor (condenser) as the end-of-line (EOL) device, for circuit supervision.

  • Clear LED indicators: each zone has its own alarm LED, plus combined indicators for Fault, Disable, and Test conditions.

User / Operation Features

  • Supports 3 access levels: different permission levels for users (e.g., installer, maintenance, end‑user) to prevent unauthorized changes.

  • Single‑person test mode: allows one person to walk the zones and test devices without triggering a full alarm.

  • Day / Night mode configurable: you can set different behaviors (e.g., sensitivity, output activation) depending on time or occupancy.

  • Manual activation capability: you can manually trigger alarm devices from the panel.

Output / Power

  • Has a supervised auxiliary 24 V DC output, useful for powering notification devices (e.g., horns, strobes).

  • Two programmable non‑addressable alarm output circuits (i.e., you can drive external alarm devices or other panels).

  • Relay contacts:

    • 2 unmonitored relays for “Fire Alarm Condition” outputs.

    • 1 unmonitored relay for Fault Condition.

Inputs / Remote Control

  • 3 voltage-free (dry contact) inputs:

    1. Remote reset

    2. Evacuation start / stop

    3. Day / Night mode switching

Expansion & Remote Interfaces

  • Can support up to 7 Repeater Panels: you can mount remote/remote annunciators to show status of zones in other locations.

  • Recessed-mounting enclosure: designed to be installed into walls neatly.

Installation & Maintenance

  • Considered “easy installation” according to the manufacturer.

  • Designed for reliable life-safety systems, with good supervision and flexibility in configuration.

Attributes Value
Weight 4.8 kg
Dimensions 402 × 337 × 99 cm