1 in stock

EN54 (EVAC-500FM) for Bettre Voice Evacuation System and Loudspeakers

SKU: EVAC-500FM
Category: , ,
Original price was: ₱18,308.25.Current price is: ₱10,663.00.
The EN54 EVAC-500FM Voice Evacuation System is a professional emergency communication solution designed for reliable fire alarm, evacuation, and public address applications in commercial and public buildings. Fully compliant with EN54-16 standards, the system supports live emergency paging, pre-recorded evacuation messages, multi-zone broadcasting, and real-time fault monitoring to ensure clear and effective communication during critical situations. Featuring a fireman’s emergency microphone with priority control, CAT6 loop redundancy connection, support for up to 32 microphone units, and communication distances up to 600 meters, the EVAC-500FM delivers dependable performance for malls, hospitals, schools, offices, airports, and other high-occupancy facilities.

1 in stock

Advanced Emergency Communication with EVAC-500FM EN54 Voice Evacuation System

EN54 EVAC-500FM Voice Evacuation System is a professional emergency voice evacuation and public address solution designed to provide fast, clear, and reliable communication during fire alarms, emergencies, and evacuation situations. Engineered to comply with EN54-16 standards, the EN54 EVAC-500FM ensures dependable performance for life safety applications in commercial buildings, hospitals, schools, malls, hotels, transportation hubs, factories, and other high-occupancy facilities.

Built for critical emergency operations, the EN54 EVAC-500FM supports live paging, pre-recorded evacuation messages, emergency alerts, and multi-zone voice broadcasting while maintaining exceptional audio clarity and system reliability.


EN54-16 Certified Emergency Voice Evacuation Solution

The EN54 EVAC-500FM Voice Evacuation System is fully compliant with EN54-16 certification requirements, ensuring that it meets international standards for voice alarm and emergency sound systems.

This certification guarantees reliable performance, continuous monitoring, fault detection, and operational stability during emergency situations where communication is critical for occupant safety.

The EN54 EVAC-500FM is specifically designed for integration into fire alarm and building evacuation systems to support emergency preparedness and compliance requirements.


Professional Fireman’s Emergency Microphone

The EN54 EVAC-500FM features a dedicated fireman’s emergency microphone that serves as a remote control unit for the voice evacuation system.

This emergency microphone provides:

  • Live emergency paging
  • Priority voice announcements
  • Manual evacuation control
  • Real-time emergency communication

The microphone operates with the highest system priority, ensuring emergency announcements override all other audio sources during critical situations.

Its lock-and-key protection mechanism restricts unauthorized access and ensures secure operation by authorized emergency personnel only.


Clear and Intelligent Emergency Audio Broadcasting

The EN54 EVAC-500FM Voice Evacuation System is engineered to deliver highly intelligible voice announcements and emergency instructions.

The system supports:

  • Live voice paging
  • Pre-recorded evacuation messages
  • Emergency alert tones
  • EVAC and alert announcements

This ensures that occupants receive clear guidance during emergency situations, helping improve evacuation efficiency and overall building safety.

When paired with EN54-certified loudspeakers, the system maintains excellent speech intelligibility even in noisy or acoustically challenging environments.


Multi-Zone Emergency Communication

One of the major advantages of the EN54 EVAC-500FM Voice Evacuation System is its flexible multi-zone broadcasting capability.

Operators can manage announcements across different building areas independently, allowing:

  • Targeted floor evacuation
  • Specific zone announcements
  • Building-wide emergency broadcasting
  • Controlled phased evacuation

This zoned communication capability helps reduce panic while improving emergency response coordination.


Real-Time System Monitoring and Fault Detection

The EN54 EVAC-500FM Voice Evacuation System includes comprehensive real-time monitoring functions to ensure continuous operational readiness.

The fireman’s microphone unit is fully monitored in real time, enabling immediate detection of:

  • Communication faults
  • Power issues
  • Microphone problems
  • System failures

Visual status indicators provide clear operational feedback for:

  • AC power status
  • DC power status
  • Fault conditions
  • Microphone activity
  • Indication testing

These monitoring features help maintain system reliability and simplify maintenance procedures.


Emergency Activation and Priority Control

The EN54 EVAC-500FM features a dedicated emergency activation button that instantly triggers all-zone evacuation broadcasting.

This allows operators to immediately activate emergency communication across the entire building during urgent situations.

The emergency microphone maintains priority control over all audio sources, ensuring that evacuation instructions are delivered without interruption.

This rapid activation capability is essential for fire alarms, evacuation procedures, and emergency response coordination.


Flexible Installation and Long-Distance Communication

The EN54 EVAC-500FM Voice Evacuation System supports communication distances of up to 600 meters, allowing flexible installation across large buildings and campuses.

The system communicates with the controller using CAT6 cable loop redundancy connections, improving communication reliability and fault tolerance.

Loop redundancy helps maintain system operation even if part of the communication cable becomes damaged during an emergency.

This design enhances system survivability and ensures stable emergency communication.


Expandable System Architecture

Each EVAC-500 voice evacuation controller supports up to 32 fireman microphone units, allowing scalable deployment for large facilities and multi-building installations.

This scalability makes the EVAC-500FM suitable for:

  • Shopping malls
  • Hospitals
  • Airports
  • Hotels
  • Factories
  • Schools and universities
  • Transportation terminals
  • Commercial complexes

The expandable architecture provides flexibility for future system growth and changing building requirements.


Integrated Emergency Power Support

The EVAC-500FM supports DC 24V phantom power supply directly from the controller, ensuring stable operation during emergency conditions.

This backup power capability helps maintain communication functionality even during power interruptions associated with fire or emergency incidents.

Reliable emergency power support is critical for maintaining uninterrupted evacuation communication.


Durable and Professional Design

Built for demanding emergency applications, the EVAC-500FM EN54 Voice Evacuation System uses durable professional-grade components designed for long-term operation.

Its robust construction ensures reliable performance in mission-critical environments where life safety communication is essential.

The professional interface allows easy operation by security personnel, emergency responders, and facility management teams.


Ideal Applications

The EVAC-500FM EN54 Voice Evacuation System is widely used in:

  • Shopping malls
  • Hospitals and healthcare facilities
  • Schools and universities
  • Office buildings
  • Hotels and resorts
  • Airports and transport terminals
  • Factories and warehouses
  • Commercial and high-rise buildings

Its combination of EN54 compliance, multi-zone control, and reliable emergency communication makes it ideal for professional life safety installations.


Key Features

  • EN54-16 certified voice evacuation system
  • Fireman’s emergency microphone with priority paging
  • Live emergency announcements and pre-recorded message support
  • Multi-zone evacuation and paging control
  • Real-time monitored microphone unit
  • AC, DC, fault, MIC, and indication test status indicators
  • Emergency activation button for all-zone EVAC operation
  • Communication distance up to 600 meters
  • CAT6 cable loop redundancy connection
  • Supports up to 32 fireman microphone units per system
  • DC 24V phantom power support
  • Lock-and-key security access control
  • High-intelligibility emergency voice communication
  • Suitable for malls, hospitals, schools, offices, and public buildings
EN54 EVAC-500FM

AttributesValue
Weight 3.8 kg
Dimensions 0.298 × 0.298 × 0.089 cm

0 reviews for EN54 (EVAC-500FM) for Bettre Voice Evacuation System and Loudspeakers

Only logged in customers who have purchased this product may leave a review.